BMLS 501-18 Applied Hematology-I 1. Quality assurance in haematology. a. Internal and external quality control including reference preparation b. Routine quality assurance protocol c. Statistical analysis i.e. Standard deviation, Co-efficient variation, accuracy and precision https://medstudyworld.blogspot.com/2021/08/quality-assurance.html https://drive.google.com/file/d/1Fzba-s9jKUoOPSz1zHLteZ532EdgYiwO/view?usp=sharing 2. Safety precautions in haematology https://medstudyworld.blogspot.com/2021/08/safety-precautions-in-hematology-lab.html https://doctorlib.info/hematology/rodak-hematology-clinical-principles-applications/3.html https://www.slideshare.net/NegashRealis/safety-and-infection-control-in-hematology-laboratory 3. Basic concepts of automation in haemotology with special reference to: a. Blood cell counter b. Coagulometer. https://medstudyworld.blogspot.com/2021/08/automation-in-blood-cell-counter.html 4. Bone marrow examination https://drive.google.com/file/d/1oEwnXCkU...
* The diagnosis and treatment of hematological illnesses depend heavily on hematology laboratories. For a hematology lab to guarantee accurate and trustworthy test findings, quality assurance is crucial. A thorough quality assurance program must be put in place in order to guarantee accurate and trustworthy test findings. This entails a number of methods and techniques meant to keep an eye on, preserve, and enhance the caliber of laboratory testing. The following are some crucial elements and procedures pertaining to hematology lab quality assurance: Standard Operating Procedures (SOPs): Maintaining uniform and standardized laboratory procedures requires the establishment and observance of clearly defined SOPs. All facets of sample collection, processing, analysis, and result reporting should be covered by SOPs. Instrument Calibration and Maintenance: To guarantee the accuracy and precision of hematology instruments, regular calibration and maintenance are required. Maintenance ...
Automation in blood cell counters, also known as hematology analyzers, has revolutionized the field of clinical laboratory testing by streamlining and improving the efficiency and accuracy of blood cell counting and analysis. Traditional manual methods for blood cell counting required technicians to manually count cells under a microscope, which was time-consuming and prone to human error. However, with the advent of automated blood cell counters, the process has been streamlined and enhanced. These sophisticated instruments utilize advanced technology to automate the process of cell counting, differentiation, and enumeration, reducing the need for manual intervention and minimizing human error. Automated blood cell counters use advanced technology, such as flow cytometry or impedance-based methods, to analyze blood samples and determine the number and types of cells present. Here's a detailed overview of automation in blood cell counters: Principles of Operation: Blood cell c...
Comments
Post a Comment